Your position: Home > Ordinary diagnosis instrument > Thermometer

MY-G032B PROFESSIONAL QUICK ACCURATE Non-Contact Body Infrared Forehead Thermometer

Backlight LCD Display;Memorization of the last 32 measurements;Precise non-contact measurements.
Item Code: MY-G032B
    Please select the information you wantX
Shipping Cost:
to
Estimated Delivery Time:
Please select the country you want to ship from
+
-
Set/Sets 2000 in Stock
  • Description
  • Download
MY-G032B PROFESSIONAL QUICK ACCURATE Non-Contact Body Infrared Forehead Thermometer

General Description
Non-contact Body Infrared Thermometer is Specially designed fo take the body temperature of a person regardless of room temperature.
Depending on various skin types and thickness, there may be temperature difference.
When the indoor temperature is significant difference, the body infrared thermometer should be placedt in that room for 15 to 20 minutes before using.

Safety Information
•This device must only be used for the purposes described in this instruction manual.
•This device must only be used in an ambient temperature range between 10 and 40 .
•Do not expose this thermometer to extreme temperature conditions of >40℃ or <0℃
•Do not expose this thermometer to electric shocks.
•Do not use the device in relative humidity higher than 85%RH
•Do not use the device near large electromagnetic fields such as found with cordless or cell phones.
•Keep the device away from water and heat, including direct sunlight,
•Do not drop or knock the device ,and dot not use if damaged
•It may affect the accuracy of measurements when the forehead is covered by hair perspiration, cap or scarf.
•Keep the measuring distance as <5cm(<2in)
•When the body infrared thermometer should be left in that room during 15to 20 minutes before using.
•It may affect the accuracy of measurements when the forehead is covered by perspiration or other factors, please take the temperature behind the ear lobe.
•Clean the glass with cotton bud lightly moistened with 70% alcohol.

Features
•Precise non-contact measurements
•Built-in laser pointer
•User selectable ℃or℉
•Automatic selection range and Display Resolution 0.1℃(0.1℉)
•Automatic Data Hold & Auto Power off
•Set Alarm value(the alarm threshold default value is 380℃(100.4℉)
•Backlight LCD Display
•Memorization of the last 32 measurements

Intended Use
•The Non-contact Body Infrared Thermometer is designed for body surface and forehead temperature measurement for infants and adult s without contacting to human body. It can be used by consumers in household environment in accordance with the ASTM 1965-1988
•Standard specification for Infrared Thermometers for Intermittent Determination of Patient Temperature.

Precaution Before Use
•In order to obtain reliable and stable results, when changing the environment to a room with a significant temperature difference, it is recommended to leave the Non-contact Body Infrared Thermometer to this ambient temperature for 15 to 20 minutes before using it.
•Depending on various skin types and thickness, there may be temperature difference.
•Do not expose the thermometer to sunlight or to water.
•Allow one minute interval between two measurement.

Normal Temperatures According To Measurement Method
Measurement MethodNormal Temp ℃ Normal Temp ℉
Rectal  36.6 to 38 97.8 to 100.4
Oral  35.5 to 37.5 95.9 to 99.5
Auxiliary 34.7 to 37.3  94.4 to 99.1
Auricular 35.8 to 38  96.4 to 100.4
Temporal(Thermo Flash) 35.8 to 37.8  96.4 to 100.0
The temperature of the human body varies throughout the day. It can also be influenced by numerous external factors: age, sex, type and thickness of skin…

Normal Temperatures According To Age
Age Temp℃  Temp ℉
0-2 years  36.4 to 38  97.5 to 100.4
3-10years  36.1 to 37.8  97.o to 100.0
11-65years  35.9 to 37.6 96.6 to 99.7
>65 years  35.8 to 37.5  96.4 to 99.5

Configuration

Technical Specifications
Normal Conditions of Use
Display Resolution 0.1℃(0.1℉)
Operating Temperature  10 to 40℃(50 to 104℉)
Humidity Rate ≤85%
Power 9V(NEDA 1604A or IEC 6LR61)
Size 88 x 42 x 175 mm(L x W x H)
Weight  122g(Without batteries)

Measuring Range
Measuring Range 32.0 to 43.0℃(90 to 109.4℉)
Accuracy ±0.3℃(0.54℉ )
Measuring Distance 5cm(2 in)
Automatic Stop  7 sec.

Non-contact Body Infrared Thermometer Precision
32 to 39.5℃/93.2 to 96.6℉  ±0.3℃/0.5℉ According to ASTM
Standard E1965-1998(2003)
36 to 39℃/96.8 to102.2℉  ±0.2℃/0.4℉
39to42.5/102.2to108.5℉ ±0.3℃/0.5℉

Use
1.Install battery
2. For the first use or when inserting new batteries ,wait 10 minutes for the warm-up of the apparatus
3. If the device is not used for along time once you turn it on again, the device will test the room temperature first and will delay turning on for one two seconds.
4.Aim towards the forehead (see the diagram below for the positioning),form a distance of 5cm(2 in),press the measuring key, the temperature is displayed immediately, Making sure there is no hair, perspiration,cosmetic or cap covered on the forehead.
5.When the room temperature is significant difference,or there is perspiration on the forehead, You can take the temperature behind the ear lobe, Making sure there on hair, perspiration, cosmetic or cap covered.
Customer Reviews
Average rating:

Share your thoughts with other customers