MY-E011 Hospital Medical adult/child anesthesia machine

Scope of application: adult, child
Item Code: MY-E011
    Please select the information you wantX
Shipping Cost:
to
Estimated Delivery Time:
Please select the country you want to ship from
+
-
Unit/Units 50 in Stock
  • Description
Specifications
1.Main body:High-strength engineering plastic rack, light, beautiful and corrosion resistant
2. Scope of application: adult, child
3. Gas source:
O2: 0.27~0.55MPa    
N2O: 0.27~0.55MPa
4. Flow meter                 
O2 : 0.1~1.0L/min   1.1~10L/min 
N20: 0.1~1.0L/min   1.1~10L/min  
Air : 0.1~10L/min
5. O2, N2O linkage and N2O Stopper
 When using nitrous oxide, oxygen concentration>25%;
 When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.
6. Flow rate of rapid oxygen supply:25~75L/min
7. Low oxygen pressure alarm:There will be sound alarm when the oxygen pressure < 0.2MPa
8. Vaporizer:it has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%. Among Halothane,
Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.
9. Respiratory circuit:working mode: all-close, semi-close, semi-open APL: 0.5~7 kPa
10. Respiratory Bellows:bellows for adults, tidal volume range:0~1500 ml
bellows for children, tidal volume range:0~300 ml
anyone can be chosen for application as required by the customer
 
Ventilator:
1. Display mode:High-definition 8.4” TFT color LCD screen display
2. Ventilation  mode:IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH(IMV, VCV, PCV)
3. Ventilation parameters:
Tidal volume:50~1500 ml (20~1500 ml)
Rate:1~99 bpm   
SIMV rate:2~20 bpm  I:E                 2:1~1:8(4:1~1:8)
Inspiratory trigger pressure:-1.0~2.0 kPa PEEP  0~2.0 kPa
Pressure range:1.0~6.0 kPa
SIGH:1.5 times the inspiratory time   (70-150 adjustable)
Inspiratory platform:0~50%
4. Parameters for ventilation monitoring   tidal volume, ventilation volume, IPPV rate, SIMV rate, 
total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform,PEEP,inspiratory trigger pressure, Inspiratory platform
(autonomous inspiratory rate, lung compliance, airway resistance,flow-volume loop, pressure-volume loop)
5. Monitoring of oxygen concentration:21%~100%
6. Security Alarm System
Oxygen Concentration alarm     upper limit setting range  21%~100%
low limit setting range    10%~80% Airway pressure alarm          upper limit setting range   0.3~6.0 kPa 
low limit setting range       0.2~5.0 kPa
Per-minute ventilation volume alarm   upper limit setting range    3.0~30L/min
low limit setting range       1.0~10L/min    