- Descrição
System Overview
Clinical Application
Abdomen
Obstetrics
Gynecology
Urology
Cardiac
Small Parts
Vascular
Imaging Modes
B, 2B, B/M, M, 4B
Main Technology
DSC (Digital Scan Converter)
DBF (Digital Beam Forming)
RDA (Real-time Dynamic Aperture)
DRA (Dynamic Receiving Apodization)
DRF (Dynamic Receiving Focusing)
DFS (Dynamic Frequency Scan)
THI (Tissue Harmonic Imaging)
Transducer Type
Convex Array Probe
Linear Array Probe
Micro-convex Probe
Intra-cavity Probe
Physical Specification
Dimension & weight
Package: (Carton)
720mm*660mm*1340mm 75kg
Monitor
15” high resolution LED Color Display
Resolution: 800 pixels×600 pixels
Contrast ratio & bright adjustable
Probe port & holder
Probe ports: 3 activated ports
Automatic recognition
Electronic probe-shift
Probe holders: 3 probe holders
Electrical power
Voltage: AC 100V-240V
Frequency: 50/60Hz
Input Power: 100VA
Fuse: F3.15AL250V (φ5×20 mm)
Operating Environment
Ambient temperature: 10°C-40°C
Relative humidity: 35%≤85%
Atmospheric pressure: 70kpa-106kpa
Transportation & Storage
Ambient temperature: -25°C-40°C
Relative humidity: 10%≤90%
Atmospheric pressure: 50kpa-106kpa
User Interface
Control panel
Backlit silica-gel (PBT) material
Full-scaled QWERTY keyboard
Independent function keys (volume-
adjustable)
Smart trackball
Intelligent 8 segment TGC
Comments
Full screen text input
Arrows (four directions)
Common-use comments preset by user
Body mark
More than 80 body marks
Information on monitor
Data & Time
Info of Hospital/Doctor/Patient
Probe Model/Frequency
Focus No. /Dist.
Frame Frequency/Correlation No
Scanning Angle/Depth
Acoustic Power/Dynamic Range
Imaging Parameter (Adjustable)
Pseudo-color Display: 6
Depth: Max. 240mm
Multiplying Factor:×0.8, ×1.0, ×1.2, ×1.5, ×1.8, ×2.0
M Speed: 810-63 levels
Local Zoom: ×2.0
TSI (Tissue Statistic Imaging)
Dynamic Range: 30-150dB
Gray Level: 256
Focus: 4 segments focusing
Focus No., Position, Distance Adjustable
Image Reverse: U/D, L/R, B/W, 90°/270°
Permanent Storage: 200images
Cine Loop: 512 frame (Auto/Manual)
Gain: Overall/8 segments TGC/Automatic
Edge Enhancement & Image Smooth
Gamma Correction & Noise Reduction
Frame Correlation: 0-255 frame
Frame Frequency: Max. 50 frame/second
One Key Full Screen Image
Optimization Key Preset
Image Management
Manual & Automatic Cineloop
Image Management System
Patient/Exam Database & Mgmt
Stored Images Slide Show
Support External USB Storage Devices
Probe Frequency
UT-C-3.5R60 Convex Array Probe
2.5/3.5/4.0/5.0MHz
UT-C-3.5R20 Micro-convex Array Probe
2.0/3.5/4.0/5.0MHz
UT-L-7.5 Linear Array Probe
5.0/6.5/7.5/10MHz
UT-C-6.5R10 Intra-cavity Probe
5.0/6.5/7.5/8.0MHz
Measurement & Report
General
Distance
Perimeter (ellipse & trace)
Area (ellipse & trace)
Surface (ellipse)
Volume (ellipse)
Angle
Len./Area Ratio
Line Straitness
Surface Straitness
Automatic Report & Print
Obstetric
BPD, CRL, GS, HC, AC, FL,
APAD, TAD, FTA,
HUMERUS, OFD, THD,
TIBIA, ULNA, AFI
GA & EDD Auto-calculation
Fetal Physiological Growth Curve
Automatic Report & Print
Gynecology
Uterus Radial Line
Intima Thickness
Ovary Volume
Dominant Follicle
Cervix Major Diameter
Corpus Cervix
Automatic Report & Print
Cardiac
Distance
Time
Heart Rate
EF Slope
Automatic Report & Print
Small Parts
Thyroid Gland
Hip Joint
Automatic Report & Print
Urology
Remnants Samples of Urine
Prostate
PSAD
Automatic Report & Print
Report Assistance
Support formula preset adapting
to different groups of patients)
Professional terms≥500 items
Diagnostic report template≥100 sets
System Inputs & Outputs
Video
VGA
S-Video
RS-232
USB2.0
RJ-45
Standard Package
Main frame
UT-C-3.5R60 convex array probe
Power cord
Fuse (2)
User’s Manual
Coupling Gel (0.25L)
Optional Accessories
UT-C-3.5R20 Micro-convex Probe
UT-L-7.5 Linear Probe
UT-C-6.5R10 Intra-cavity Probe
USB disk/CF card/SD card
Laser Pinter
Video Printer
Pedal switch
Puncture guide frame
Certificates
Quality Standards
ISO9001
ISO13485
CMD
Design Standards
EN ISO13485 and EN ISO10993-1
MDD93/42/EEC and EN60601-1-4
EN14971 and EN980
EN60601-1 and IEC60601-1
EN60601-1-2 and IEC60601-1-2
EN60601-2-37 and IEC60601-2-37
EN61157 and EN62304