- Description
Specifications
Display screen:
10.4”LCD, resolution: 640 × 480
Throughput:
≥60 samples/hour
Memory:
35,000 sample results inclusive of the histograms
Power supply:
AC100-240V 50/60Hz
Printer:
Built-in thermal recorder, optional external printer, eight report formats
3-part 23 parameters hematology analyzer
MY-B006E Hematology Analyzer is a 3-part differential of WBC blood cell counter. It is advantaged at digital technology, auto-relocation separatrix, intelligent flush clog, dual measuring technology (with time and volume) to ensure precise of the test results.
Automated & User-friendly Interface
- Auto sampler
- 10.4” LCD display with the test items, reference value and three histograms
- Online alert for the abnormal results
- Keyboard & mouse operation
- Windows OS
- Easy to search and edit patient information
- Storage capacity: 35,000 sample results inclusive of histograms
- Optional printout formats
- Real time guideline for easy operation
Accurate Results & Low Sample Consumption
- Accurate analysis technology with low sample consumption:
- Venous mode: 9.6ul
- Capillary mode: 9.6ul
- Pre-diluted mode: 20ul
Easy Maintenance & Environment-friendly System
- Adjustable sample probe for various cuvettes
- With liquid sensor to alarm low reagent
- Cyanide-free Lyse
- Automated & Systematic diagnosis and maintenance with alerts
- Liquid tubing and electronic circuit separately for easy maintenance
- Closed reagent tubing to avoid contamination
Perfect QC System
- Calibration mode: manual and auto
- QC mode: L-J, , X-B, SD, CV, QC histogram
Unique sweep flow technology to avoid recounting
Auto-relocation separatrix to exact the differential of WBC
Intelligent PLT histogram fit technology to improve the precision of PLT
Auto sample probe cleaning
Auto standby and wakeup
High voltage burn, soaking and flush clog with real time monitor
Three sample modes: venous, capillary and pre-diluted
PE-6000 Hematology Analyzer
3-part 23 parameters hematology analyzer
Specifications
Principle: Electrical resistance for counting, hemiglobincyanide method and SFT method for hemoglobin
Parameters: 3-part differential of WBC;
20 parameters + 3 color histograms (WBC/RBC/PLT)
Sample Consumption: Venous Mode: 9.6μL
Capillary Mode: 9.6μL
Pre-diluted Mode: 20μL
Working Mode: Double passages counting detection + independent HGB measurement system; 24 hours with auto standby
Operation Mode: Windows operation system with keyboard&mouse input
Throughput: ≥60 samples/hour
Storage: 35,000 sample results inclusive of the histogramsQC mode: L-J, , X-B, SD, CV, QC histogram
Cross Contamination Ratio: WBC/RBC/HGB<0.5%, PLT<1%
Performance:
Parameter Repeatability (CV %) Linear Range
WBC ≤2.5% 0.00-99.9×109/L
RBC ≤2.0% 0.00-9.99×1012/L
HGB ≤1.5% 0-300g/L
MCV ≤0.4% 40-150fL
PLT ≤5.0% 0-999×109/L
Display: 10.4” LCD, resolution: 640 × 480
Reference Value: Baby, Kid, Woman, Man, Normal and Customization
Interface: 2 × USB, 1 × parallel (for external printer), 1 × VGA (for external monitor), 2 × PS/2, 2 × RS-232(for network);
Printer: Built-in thermal recorder, optional external printer, eight report formats
Environment Requirement: Temperature: 15℃~35℃; Humidity: 10%-90%;
Specifications | ||
Principle: | Electrical resistance for counting, hemiglobincyanide method and SFT method for hemoglobin | |
Parameters: | 3-part differential of WBC; 20 parameters + 3 color histograms (WBC/RBC/PLT) | |
Sample Consumption | Venous Mode: 9.6μL, Capillary Mode: 9.6μL, Pre-diluted Mode: 20μL | |
Working Mode: | Double passages counting detection + independent HGB measurement system; 24 hours with auto standby | |
Operation Mode: | Windows operation system with keyboard&mouse input | |
Throughput: | ≥60 samples/hour | |
Storage: | 35,000 sample results inclusive of the histograms | |
QC mode: | L-J, , X-B, SD, CV, QC | |
Cross Contamination Ratio: | WBC/RBC/HGB<0.5%, PLT<1% | |
Performance: | Parameter Repeatability (CV %) | Linear Range |
WBC ≤2.5% | 0.00-99.9×109/L | |
RBC ≤2.0% | 0.00-9.99×1012/L | |
HGB ≤1.5% | 0-300g/L | |
MCV ≤0.4% | 40-150fL | |
PLT ≤5.0% | 0-999×109/L | |
Display: | 10.4” LCD, resolution: 640 × 480 | |
Reference Value: | Baby, Kid, Woman, Man, Normal and Customization | |
Interface: | 2 × USB, 1 × parallel (for external printer), 1 × VGA (for external monitor), 2 × PS/2, 2 × RS-232(for network); | |
Printer: | Built-in thermal recorder, optional external printer, eight report formats |
|
Environment Requirement: | Temperature: 15℃~35℃; Humidity: 10%-90%; |
|
Power supply: | AC100-240V 50/60Hz |