- Description
Specifications
Display screen:
8.4” LCD ,resolution:640*480
Throughput:
35 samples/hour
Memory:
Up to 12,000 results inclusive of the histograms
Power supply:
AC100-240V 50/60Hz
3-part 23 parameters hematology analyzer
MY-B006B Hematology Analyzer is a 3-part differential of WBC blood cell counter. It is advantaged at digital technology, auto-relocation separatrix, intelligent flush clog, dual measuring technology (with time and volume) to ensure precise of the test results.
Automated & User-friendly Interface
- Auto sampler
- 8.4” LCD display with the test items, reference value and three histograms
- Online alert for the abnormal results
- Keyboard & mouse operation
- Windows OS
- Easy to search and edit patient information
- Storage capacity: 12,000 sample results inclusive of histograms
- Optional printout formats
- Real time guideline for easy operation
Accurate Results & Low Sample Consumption
- Accurate analysis technology with low sample consumption:
- Venous mode: 9.6ul
- Capillary mode: 9.6ul
- Pre-diluted mode: 20ul
Easy Maintenance & Environment-friendly System
- Adjustable sample probe for various cuvettes
- With liquid sensor to alarm low reagent
- Cyanide-free Lyse
- Automated & Systematic diagnosis and maintenance with alerts
- Liquid tubing and electronic circuit separately for easy maintenance
- Closed reagent tubing to avoid contamination
Perfect QC System
- Calibration mode: manual and auto
- QC mode: L-J, X, X-B, SD, CV, QC histogram
Advanced Technology
- Unique sweep flow technology to avoid recounting
- Auto-relocation separatrix to exact the differential of WBC
- Intelligent PLT histogram fit technology to improve the precision of PLT
- Auto sample probe cleaning
- Auto standby and wakeup
- High voltage burn, soaking and flush clog with real time moni
Technical Specifications: | ||
Principle: | Electrical resistance for counting, hemiglobincyanide method and SFT method for hemoglobin | |
Parameters: | 3-part differential of WBC; 20 parameters + 3 color histograms (WBC/RBC/PLT) | |
Sample Volume | Venous Mode: 9.6μL Capillary Mode: 9.6μLPre-diluted: 20μL | |
Working Mode: | Counting passages detection + independent HGB measurement system; 24hours with auto standby | |
Operation Mode: | Windows operation system with ,keyboard &mouse input | |
Throughput: | 35 samples/hour | |
Data Storage: | Up to 12,000 results inclusive of the histograms | |
QC mode: | L-J, ,X-B , SD, CV, QC histograms | |
Calibration Mode: | Relatively independent manual calibration and auto calibration in three detecting modes | |
Cross Contamination Ratio | WBC,RBC, HGB<0.5%, PLT<1% |
|
Performance | Parameter Repeatability (CV %) | Linear Range |
WBC≤2.5% | 0.00-99.9×108/L | |
RBC ≤2.0% | 0.00-9.99×1012/L | |
HGB ≤1.5% | 0-300.0g/L | |
MCV≤0.4% | 40-150fL | |
PL T ≤5.0%(100-500) | 0-999×109/L | |
Display: | 8.4” LCD ,resolution:640*480 | |
Reference value | Baby, kid, women, man, normal and customization | |
Interface: | 2 × USB, 1 × parallel (for external printer), 1 × VGA (for external monitor), 2 × PS/2, 2 × RS-232(for network); | |
Printout | I Built-in thermal recorder, optional external printer, eight report formats | |
WorkingEnvironment | Temperature: 15℃~35℃; Humidity: 10%-90%; | |
Power Requirement | AC100-240V 50/60Hz |